Anti-slip mats
Reliable stability and load-bearing capacity
Applications
KARGOTEC® basic
Our all-rounder for standard applications
Technical Details
Coefficient of sliding friction:
Tested value: µ=0.7 at 3 to 20 mm thickness
Practical calculation value: µ= 0.6
Maximum permissible Compressive load:
approx. 100 t/m² at 3 mm thickness
approx. 120 t/m² at 8 mm thickness
(according to VDI 2700 Sheet 15, max. 30% compression is permissible)
Service temperature range:
– 30 °C to + 100 °C
Tensile strength:
min. 0.6 N/mm2 (DIN EN ISO 1798)
Elongation at break:
min. 60 % (DIN EN ISO 1798)
KARGOTEC® special plus
Our upgrade for increased surface loads
Technical Details
Coefficient of Sliding friction:
Teste value: µ=0.8 at 3 to 20 mm thickness
practice-related calculated value: µ=0.6
Maximum permissible Compressive load:
approx. 180 t/m² at 3 mm thickness
approx. 290 t/m² at 8 mm thickness
(according to VDI 2700 Sheet 15, max. 30% compression is permissible)
Service temperature range:
– 30 °C to + 100 °C
Tensile strength:
min. 0.6 N/mm2 (DIN EN ISO 1798)
Elongation at break:
min. 60 % (DIN EN ISO 1798
KARGOTEC® protect
Our Solution for demanding loads
Technical Details
Coefficient of Sliding friction:
Teste value: µ=0.9 at 3 to 10 mm thickness
practice-related calculated value: µ=0.6
Maximum permissible Compressive load:
approx. 270 t/m² at 3 mm thickness
approx. 270 t/m² at 8 mm thickness
(according to VDI 2700 Sheet 15, max. 30% compression is permissible)
Service temperature range:
-30°C to +100°C
Tensile strength:
approx. 0.8 N/mm² (DIN EN ISO 1798)
Elongation at break:
min. 120 % (DIN EN ISO 1798)
KARGOTEC® secure
Extremely heavy loads securely supported
Technical Details
Coefficient of Sliding friction:
Teste value: µ=0.8 at 8 and 10 mm thickness
practice-related calculated value µ=0.6
Maximum permissible Compressive load:
approx. 500 t/m² at 8 mm thickness
approx. 500 t/m² at 10 mm thickness
(according to VDI 2700 Sheet 15, max. 30% compression is permissible)
Service temperature range:
-30°C to +100°C
Tensile strength:
approx. 0.6 N/mm² (DIN EN ISO 1798)
Elongation at break:
min. 60 % (DIN EN ISO 1798)
Applications
Pallets and Mesh oxes
Metal Rod Coils
Paper Coils
They should be placed under and between the paper coils to support and relieve the load, significantly reducing the number of securing straps required.
Pipes
Need help selecting the right material?
The right choice depends on the medium, temperature, and mechanical load. We are happy to advise you on the optimal material solution for your application.